Combination of Animal Ventilator to Anesthesia System
This program is the combination of anesthesia machine and ventilator. While keeping the animal under anesthesia, it provides a certain volume (tidal volume) of oxygen and respiratory rate to support the normal breathing of animals. It can meet the requirements of long surgeries or surgeries on animals suffering from certain diseases (such as cardiovascular and cerebrovascular diseases, hypertension, cerebral infarction, thrombosis), and suitable for mice, rats, rabbits, cats and other animals within 5kg.
Overview
Features
- High accuracy vaporizer (Each one has an independent test report).
- Dual channels: Independent switches for chamber and mask channels.
- Integrated design, no need to install vaporizer and
- Low stress induction chamber, supporting active recycling.
- High efficiency gas evacuation system preventing the researchers from exposure to anesthesia gas.
- Special anesthesia mask for stereotaxic, which does not hinder experimental operation.
Technical Specifications
Air Pump:
Voltage:110-120v
Frequency:60Hz
Air Flow:18L/min
AMP(A):0.36
WATT(W):20
Maximum Size(mm):163*128*111
Vaporizer:
Flowmeter specifications:0-4L/min
Concentration range:Isoflurane:0-5%;Sevoflurane:0-8%
Concentration output accuracy:±0.1(0-1%);±0.15(>1%)
Capacity:≥120ml
Operating temperature range:10-35℃
Chamber(V105):
Size:310mm*150mm*190mm
Canister:
Net weight: 800g,absorb 200g gas
Gas Evacuation Apparatus:
Size: 232mm*200mm*184mm
Net Weigh(without a canister): 2.9kg
Display screen:2 inch, 128*64 Resolution
The weight: 1~2000g
Flow: 8 ~ 60LPM
Noise: ≤50dB
Working power:100V-240V,50/60Hz,1.5A
Order List
| Combination of Animal Ventilator to Anesthesia System | Model | Product Description | Remarks |
| R510-30 | Anesthesia Air Pump | ||
| TAIJI-IE | Compact Small Animal Anesthesia Machine, Isoflurane, Easy Fill, 0-4L | ||
| V105 | Low Stress Anesthesia Induction Chamber, for Mice and Rats | For Active Scavenging | |
| V100 | Induction Chamber-mouse (15cm*10cm*10cm) | For Passive Scavenging | |
| V101 | Induction Chamber-rat (24cm*12cm*18cm) | ||
| R415 | Small Animal Ventilator | ||
| R415-AP | Accessory package for Anesthesia and Ventilator | ||
| RE20-R | Endotracheal intubation tube for rat (length 50mm) | ||
| RE20-M | Endotracheal intubation tube for mouse (length 25mm) | ||
| R510-31-6 | Gas Filter Canister, Large, packge of 6 | ||
| R546Pro | Gas Evacuation Apparatus with Weight Monitoring, 110-240V | For Active Scavenging | |
| R510-T | Compact Small Animal Anesthesia Machine Trolley |